Error Codes
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
Display Definition Corrective Action
OP
Open thermistor error
Check thermistor. Replace if inoperative.
Check wiring diagram between control and
thermistor. Refer to wiring diagram for proper
wiring.
Check control. Replace if inoperative.
SH
Shorted thermistor error
Check thermistor. Replace if inoperative.
Check wiring between control and thermistor.
Refer to wiring diagram for proper wiring.
Check control. Replace if inoperative.
AF - 1
Airflow switch closed when cycle
started
Check airflow switch. Replace if inoperative.
AF - 2
Airflow switch failed to close after
cycle started
Check airflow switch. Replace if inoperative.